NATA accredited · Type A inspection body

Your facade test, independently verified.

beTcs Asia-Pacific witnesses, supervises and reports on performance testing of curtain walls, facades, windows and doors, so builders and facade consultants can accept a system with confidence. In Australia and at laboratories in China, Thailand, South Korea and Vietnam.

Sloped glazing performance mock-up rigged for testing in a full-scale laboratory
Performance mock-up under test
100+facade performance tests witnessed
8overseas laboratories in four countries
11 yrsin CSIRO's facade testing laboratory
2019NATA accredited since, No. 20528
Type A inspection

No stake in the outcome.

As a Type A inspection body, beTcs is independent of the facade contractor, the manufacturer and the test laboratory. Our only interest is whether the specimen meets your specification, and whether the test properly proved it.

The risks we take off your hands
  • Tests run to the wrong procedure or parameters, with results that won't stand up
  • Laboratories lacking the accreditation, capacity or calibrated equipment the test needs
  • Retests, programme delays and disputes over what was agreed
  • Accepting a facade system that hasn't demonstrated its performance

How we work

From test planning to the accredited report.

  1. Before the test

    • Advise on the test schedule and PMU configuration
    • Vet the laboratory's accreditation, scope, equipment range and calibration
    • Confirm procedures, parameters and acceptance criteria are agreed by all parties
  2. During the test

    • Witness and supervise every test sequence
    • Ensure the specified standards and agreed parameters are correctly applied
    • Record observations, failures and remediation as they happen
  3. After the test

    • Analyse results independently against the performance requirements
    • Issue a NATA-accredited inspection report documenting the tests, results and compliance
Inspecting a cladding performance mock-up during installation at a test laboratory
Led by experience

From the laboratory that wrote the method.

Our principal inspector spent 20 years at CSIRO, the last 11 in its Facade Engineering & Weather Performance of Buildings laboratory, where the SIROWET method was developed before becoming AS/NZS 4284.

That work spanned full-scale facade testing in a NATA-accredited laboratory and test witnessing throughout China and South-East Asia.

What we inspect

Laboratory test witnessing

Curtain wall, facade, window and door prototypes tested for air, water and structural performance, in Australia and overseas.

AS/NZS 4284 · AS/NZS 4420.1 · ASTM · AAMA 501 · BS EN

Laboratory witnessing →

Impact performance testing

Soft- and hard-body impact testing of cladding panels and facade elements, using our own impactors to ISO 7892.

CWCT TN75 & TN76 · BS EN 12600, 13049, 14019

Impact testing →

Field testing of installed facades

On-site water penetration checks and quality assurance of installed curtain walls, windows and sloped glazing.

FGIA/AAMA 501.2 & 503 · BS EN 13051

Field testing →

NCC weatherproofing verification

Wall systems verified against NCC Performance Requirements F3P1 and H2P2 for water penetration.

NCC Volume One F3V1 · Volume Two H2V1

NCC verification →

Selected case studies

More than 70 projects across Australia and overseas. See all projects.

55 Pitt Street, Sydney

55 Pitt Street

Sydney

Client & builder
Mirvac
Facade
BM Windows
Laboratory
Winwall Technology, Vietnam

AS/NZS 4284:2008 · CWCT TN75 & TN76 · AAMA 501.1-17

Proof of concept for full-storey bespoke bi-fold windows: cyclic fatigue of the operating mechanism, lateral load and dynamic wind pressure. Plus almost 200 soft- and hard-body impacts across numerous terracotta tile profiles.

Queen's Wharf Towers 5 and 6, Brisbane

Queen's Wharf Towers 5 & 6

Brisbane

Client
QWB Residential Precinct Operation
Builder
FEC Constructions
Facade
Yuanda Australia
Laboratory
Shenyang Kezheng, China

AS/NZS 4284:2008

Dead weights applied to planter boxes to load the curtain wall panels, and a large, bespoke lift-and-tilt operable window assessed against the specified performance parameters.

133 Liverpool Street, Sydney

133 Liverpool Street

Sydney

Client & builder
Deicorp
Facade
Core Facade Delivery Management
Supplier
BM Windows
Laboratory
Winwall Technology, Vietnam

AS/NZS 4284:2008

Complex curtain wall geometry with very large, horizontally spanning vision IGUs, demanding careful analysis of the structural test results.

Clients

Builders, facade contractors, manufacturers and asset owners.

MirvacFEC ConstructionsMultiplexLendleaseJohn HollandBuiltWatpacHindmarshLipmanCNYDPermasteelisa GroupYuanda AustraliaBM Windows FaçadeAustech FacadesCoreSRG GlobalKaneSekisui HouseCSRBrickworks Building ProductsViridianWestfieldQueensland HealthSA HealthWA Department of Health

Bring us in before the test schedule is fixed.

Independent advice is worth most before the PMU is designed and the laboratory is booked.

Discuss your project